Understanding the protection in your consumer unit helps you ask better questions when planning electrical improvements.

Short answer

An RCD detects an imbalance between outgoing and returning current and disconnects the supply to reduce certain electric shock risks. An RCBO combines that residual-current protection with overload and short-circuit protection for an individual circuit. Separate RCBOs can limit the spread of a fault, but the right arrangement depends on the installation and its test results.

What the different devices actually protect

RCD: residual current device

Electricity normally flows out through the line conductor and returns through neutral. An RCD monitors the balance between those currents. If enough current takes another path, perhaps through damaged insulation or a person touching a faulty appliance, the device disconnects. It is an important protective measure, not permission to touch wiring or use damaged equipment. It cannot prevent every kind of electric shock.

MCB: miniature circuit breaker

An MCB responds to excessive current caused by overloads or short circuits. It protects the circuit wiring against those conditions, rather than providing the same additional shock protection as a 30 mA RCD. Many older arrangements combine several individual MCBs with a shared RCD upstream. Looking at one switch without understanding that arrangement can lead to the wrong conclusion about what protection exists.

RCBO: combined protection

An RCBO brings the two functions together for its circuit. It still needs correct selection, sound wiring and proper testing. A new device does not mend a damaged cable or make an unsuitable circuit suitable for a larger appliance. Start with the circuit requirements, not just the letters on the front.

Why one fault sometimes switches off several rooms

In a split-load consumer unit, one RCD may protect a group of circuits. An earth-leakage fault on the washing machine circuit can therefore also disconnect lighting or sockets elsewhere in that group. The individual MCB may remain on because the current was not high enough to operate its overload or short-circuit function. That combination is quite possible and does not by itself mean the devices are broken.

With individual RCBOs, a residual-current fault should normally disconnect the affected circuit rather than every circuit in a shared group. This improves continuity, especially where losing lights alongside sockets would make moving around difficult. It does not mean that only one switch can ever operate: upstream protection, supply faults and faults affecting several circuits can still interrupt a wider area.

Small standing leakage currents from several electronic appliances can also add together on a shared RCD. Separating circuits may improve resilience, but persistent tripping deserves investigation rather than assumptions. Our RCD tripping guide explains the symptoms to record before arranging testing. Write down which device operated, what was running and whether rain or a particular appliance seemed relevant.

Does every home need an RCBO consumer unit?

There is no useful blanket answer based only on the age or appearance of the board. An electrician considers the existing protective measures, circuit condition, current requirements and scope of proposed work. A serviceable installation does not automatically require complete replacement just because a different arrangement would now be preferred for a new installation.

For a planned board replacement, individual RCBOs are often worth discussing because of the improved circuit separation. The design also needs to consider surge protection, the suitability of device types for connected equipment and any other protective devices required for the particular premises. Those are separate decisions, not features implied by the word RCBO.

Existing circuit test results matter. Borrowed neutrals, insulation problems or incorrect connections may become apparent when circuits are separated or more sensitive protection is fitted. A responsible proposal explains how investigation and remedial work will be handled, rather than promising a simple swap regardless of what is found. Read about consumer unit upgrades before comparing specifications from different contractors.

Device type matters as well as the label

Type AC, Type A and equipment requirements

Residual-current devices respond to particular fault-current waveforms. Modern electronic equipment can influence the type required, so an electrician must choose a suitable device for the load and the applicable wiring requirements. Type A devices are commonly relevant in modern domestic installations, but some equipment needs different or additional arrangements. An EV charger, for example, needs assessment against its own protective requirements and manufacturer instructions.

The current rating and residual operating current are different things. A marking such as 30 mA relates to residual-current sensitivity, while an ampere rating concerns load or device capacity. Neither number alone establishes whether a device is suitable. Breaking capacity, characteristics and the surrounding assembly also matter.

Components must be compatible with the consumer unit manufacturer's approved arrangements. Similar appearance or the ability to clip onto a rail is not evidence that a replacement device is acceptable. Do not buy a selection of breakers online and ask someone to fit whatever arrives. Give the electrician the equipment details and let the design determine the parts.

Want a fixed written quote? Call 01235 430442 or send us the details.

What a sensible upgrade assessment includes

An assessment should cover the supply characteristics, earthing, main protective bonding, circuit condition and practical space around the board. The electrician may need access to sockets, lights and connected equipment for inspection and testing. Tell them about inaccessible areas, previous alterations and any circuits that are already unreliable, even if you have learned to live with the problem.

Ask how circuits will be identified and how the work will affect the household during the interruption. Freezers, home working, alarms and equipment supporting health needs all require advance planning. Where continuity is especially important, tell the contractor before the visit rather than expecting a protective device alone to solve the issue.

Useful questions include whether the proposal includes appropriate surge protection, what happens if testing identifies defects, and which records you will receive. The related earthing and bonding guide explains another common prerequisite. A clear written scope is more valuable than a headline promising the most switches or the newest-looking enclosure.

Testing, paperwork and Building Regulations

A consumer unit replacement is normally notifiable electrical work under Building Regulations in England. The route for meeting that requirement should be agreed before work begins, and an Electrical Installation Certificate should be provided for the installation work. Building Regulations evidence and the electrical certificate serve different purposes; do not assume one document automatically replaces the other.

The electrician should test the completed work and record relevant results, including operation of protective devices. Pressing a test button is a useful user check, but it is not a substitute for the initial verification needed after installation. Keep the certificate, circuit schedule and any notification evidence with the property records, not just in a contractor's message thread.

For existing installations, an EICR assesses condition and records findings within its agreed scope. It is not the same as an installation certificate for new work. Our installation certificates page explains the distinction. Ask what paperwork is included before authorising the work, especially if the upgrade is part of a sale or wider refurbishment.

When to call an electrician

Arrange professional investigation if protection repeatedly operates, will not reset, or seems linked to a particular appliance, damp area or recent alteration. Stop using equipment that appears damaged. If there is smoke, fire, sparking or a strong burning smell, keep clear, switch off only if safe and use the emergency services where appropriate. Do not remove the consumer unit cover to investigate.

Repeated resetting can re-energise a fault. Do not hold a switch in position, bypass an RCD or replace a device with a larger rating to stop trips. Keep a simple record of events instead and arrange electrical fault finding. If a test button fails to operate its device when used according to the instructions, seek advice promptly rather than assuming the protection still works.

Adtec Electrical Services Ltd undertakes domestic electrical work and testing, alongside commercial and industrial work. To discuss an upgrade, contact Adtec with a photograph of the closed consumer unit, a description of the planned work and any symptoms. Adtec gives a fixed written quote after seeing the job; the assessment determines whether targeted repairs, a board replacement or wider investigation is appropriate.

Want a fixed written quote? Call 01235 430442 or send us the details.

Frequently asked questions

Both can provide residual-current protection when correctly selected and installed. The main practical advantage of individual RCBOs is that each circuit has its own combined protection, which can reduce the extent of an interruption.

Sometimes an existing board can accommodate a suitable RCBO, but compatibility and the wiring arrangement must be checked. This is not a homeowner replacement task, even when the new device looks similar.

They will not repair faulty appliances or insulation. They may keep a problem confined to one circuit, making it easier to identify which area needs investigation.

Follow the device manufacturer’s instructions and the notices supplied with the installation. Plan for the associated loss of power before testing, and ask an electrician if you are unsure which device serves important equipment.

No, an RCBO does not perform the job of a surge protective device. Surge protection is considered separately as part of the installation design.